Determination of unbound piperaquine in human plasma

Web version

T1530-11-74

American Association of Pharmaceutical Scientists (AAPS), PharmSci 360, Advancing Pharmaceutical Sciences, Careers, and Community

Authors

Liusheng Huang1, Vong Sok1, Erika Wallender1, Grant Dorsey2, Philip Rosenthal2, Francesca Aweeka1

  1. Drug Research Unit; Department of Clinical Pharmacy; University of California, San Francisco.
  2. Department of Medicine; University of California, San Francisco.

Contact information

[email protected]

Jump below to

Purpose

Piperaquine (PQ) is a highly protein-bound drug commonly combined with dihydroartemisinin for the treatment and prevention of malaria. Variation in plasma protein contents during pregnancy and infancy may affect the pharmacokinetic exposure of unbound drug, leading to alteration of clinical outcomes. Previously we reported total PQ exposure was 40% lower in pregnant women and children compared to non-pregnant adults, but unbound PQ exposure remains unclear. Therefore, we developed a LC/MS/MS method to determine unbound PQ exposure in human plasma.

Objective(s)

To develop a sensitive method for quantitation of unbound PQ in human plasma with a lower limit of quantification (LLOQ) of ≤50 pg/mL.

Method(s)

Ultrafiltration

Microcon Ultracel® centrifugal filters (10k NMWL) were used to remove protein- bound drug. Plasma (100µL) was added to the benzalkonium chloride (BAK) treated filter cup and centrifuged at 13,400 rcf at 37 ºC for 9 min. The filtrate was mixed with ½ volume of PQ-d6 (IS).

LC-MS/MS system

A Sciex TripleQuad 6500+ Tandem Mass Spectrometer coupled with a Water UPLC (I Class) system was used (Fig. 1).

diagram shows 100 µL plasma in a machine then an arrow points from that to a larger machine

Fig. 1. Work flow

Result(s)

MS/MS optimization

APCI+ was used to minimize matrix effect that was significant when ESI+ was used.

Table 1. Optimized MS/MS parameters

Source parameters

T, °C

CUR

NC

Gas1

CAD

 

400

30

4

45

9

Compound parameters

DP

EP

CE

CXP

Time, ms

PQ, 535/288

86

10

45

9

50

PQ-d6 (IS), 541/294

85

10

45

9

50

Note: T, source temperature, CUR, curtain gas, NC, nebulizer current, Gas 1, ion source gas, CAD, collision-assisted dissociation. DP, declustering potential, EP, entrance potential, CE, collision energy, CXP, collision cell exit potential.

LC optimization

PFP (30x2.1mm, 1.7µm, Waters Corp) was used for separation, which retained PQ better than PFP(50x2.1mm, 1.9µm, Agilent Tech). The mobile phase A=20mM NH4FA, 0.14%TFA, B=0.1%TFA in acetonitrile [later modified to methanol-acetonitrile(4;1, v/v)]. Flow rate 0.8mL/min.

Table 2. LC gradient

Time, min

0

0.1

1.0

1.40

1.41

1.50

Solvent B,%

30

30

80

80

30

30

With the gradient program (Table 2), the retention times for PQ and the IS (PQ-d6) are both 0.68 min (Fig. 2).

chart shows intensity against retention time which peaks between 3000 and 4000 at 6.8 minutes with the peak labelled signal/noise = 18. a chemical formula diagram also appears.

Fig 2. Chromatogram of PQ at LLOQ level (0.02 ng/mL).

Ultrafiltration

To test for nonspecific binding on the ultrafiltration device, PQ was dissolved in 10% acetonitrile 0.5% formic acid and the solutions were directly filtered through the device. We observed 50% binding to the filter devices at 10 ng/mL PQ and 29% at 100 ng/mL PQ. However, following treatment of the filters with 5% BAK, PQ was fully recovered from the ultrafiltration (Table 3).

Table 3.

 

Direct filtration

Pretreated with BAK

PQ, ng/mL

10

100

0.1

10

Recovery, %

50

71

103

104

Validation

The method was validated based on the guidelines from NIH-funded Clinical Pharmacology Quality Assurance Program. Calibrators (0.02, 0.05, 0.1, 0.2, 05, 1, 2, 5 ng/mL) and QC samples (0.06, 1.5, 4 ng/mL) were prepared in plasma filtrate with or without BAK pre-treatment.

  • Intra-inter-day precision and accuracy were within ±15% (Table 4).

  • Matrix effect was evaluated with 6 lots of plasma filtrate spiked with 0.06, 1.5, 4 ng/mL PQ. The CV% of slopes from linear regression of the 6 lots samples was 3.2% (<5%), suggesting matrix effect did not impact quantitation of PQ.

Table 4.

 

Intra-day

Inter-day

Nominal*

0.02

0.06

1.5

4

0.02

0.06

1.5

4

CV%

6.2-15

4.4-11

4.7-11

2.5-8.6

12

9.7

8.5

7.0

Dev%

3.8-15

-8.9-1.6

-7.3-3.2

-0.67-9.8

9.9

-4.9

-2.9

4.2

n

6

6

6

6

18

18

18

18

Application

We carried out a pilot analysis of clinical samples from two pregnant woman. When the method was applied to the 1st subject, there was an interfering peak for PQ. We resolved it after mobile phase B was modified to methanol-acetonitrile (4:1) with 0.1%TFA. The concentration-time profile of unbound and total PQ from a pregnant woman is shown in Fig. 3. The unbound PQ ranged from 0.19 -0.39% of the total PQ concentration.

two graphs showing total versus unbound PQ over PK time, total PQ peaks at about 260 at 5 hours, unbound PQ peaks at about .9 at 6 hours.

Fig. 3. Concentration-time profile for unbound and total PQ from a pregnant woman receiving PQ chemoprevention.

Conclusion(s)

A sensitive LC-MS/MS method was developed for quantification of unbound PQ in human plasma with an LLOQ at 0.02 ng/mL. To our best knowledge, this is the most sensitive method for PQ quantitation. Application to a clinical pharmacokinetic study is ongoing.

Funding​/​acknow­ledg­ment

This work was supported by NIAID (# R01AI117001 and 4P01HD059454-09). We thank Amelia Deitchman, David Gingrich and Florence Marzan.

Other versions